Drop-Out Fuse Cutout

Product Description

Drop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device, To be connected with incoming feeder of distribution transformer or distribution lines, it mainly protect transformer or lines from short circuit and overload, and on/off loading current, Drop-out fuse cutout is composed of insulate insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube, Fuse tube is composed of inside arc-extinguishing tube. Outer phenolic compound paper tube or epoxy glass tube, Load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure for switching on-off loading current.

At normally working via fuse link tightened the fuse tube is fixed to form up of close position. In case system occur faults, fault current result In fuse melt immediately and take place electric arc, which let arc-extinguishing tube being heated and explode a lot of gas, This will produce high pressure and blow off the arc along with tube. After fuse link melt moving contact has no tightened strength again, mechanism is locked and fuse tube drop out, Cutout now is in open position, When it needs to switch off during cutout loading, operator shall via insulating operating sticks pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.

Note: Other marks refer to the following conditions

  1. The product that has been improved greatly, but not the developed product needs to be distinguished from the original model, so, it is marked with A, B, C ….
  2. The product that is combined with other functional units under the same variety, it is expressed with the upper case letter of Chinesephonetid alphabet of functional unit, for example,

F—With load breaking device

B—With arrester

  1. The derived product that is applicable for the special environment conditions is expressed with the following codes and brackets, for example,
  2. Th—Damp-hot zone type TA—Dry-hot zone type G—High altitudetype W—Pollution resistancetype

Table 1

Terminal Connectors    
connector Type wire size Catalog no.suffix
Parallel-Groove Clamp, tin-plated bronze #6–4/0 ACSR or 250 MCM -D
Small Eyebolts #8–2/0 stranded -J
Large Eyebolts # 6–4/0 ACSR or 250 MCM -M

Table 2

Mounting Brackets  
Mounting Brackets Type Catalog no.suffix
NEMA A Bracket -A
NEMA Heavy Duty “B” Bracket with carriage bolts M12*50 for adjust bracket to fit crossarms. -B
Extended Crossarm Bracket (Horizontal section is 70mm longer than NEMA “B” bracket) -E
Pole Mounting Bracket -P